PDF全文下载:20160100023
孙素莉,程媛,赵文英,武智强,范志先
(青岛科技大学 化工学院,山东 青岛 266042)
摘要:采用离子色谱法建立偏二甲肼的定量分析方法,并对样品中偏二甲肼的含量进行测定。以20 mmol·L-1甲烷磺酸溶液为淋洗液,使用CS12A(250 mm×4 mm)阳离子交换柱,电导检测器,外标法定量。测得偏二甲肼的检出限为005 mg·L-1,在25~1 000 mg·L-1浓度范围内,线性回归方程为Y=502 686X+239 795,R=0999 7。40 mg·L-1和400 mg·L-1水平的平均回收率分别为997%和995%,8次样品重复测定的相对标准偏差为110%。结果表明,采用离子色谱测定偏二甲肼的方法快速、准确、可靠。
关键词: 偏二甲肼;离子色谱;外标法
中图分类号: O 614 文献标志码:A
Determination of Unsymmtric Dimethyl Hydrazine by Ion Chromatography
SUN Suli, CHENG Yuan, ZHAO Wenying, WU Zhiqiang, FAN Zhixian
(College of Chemical Engineering, Qingdao University of Science and Technology, Qingdao 266042, China)
Abstract: Ion chromatograph was adopted to construct the quantitative analysis methods of the unsymmtric dimethyl hydrazine, to determine the content of the sample. In this method, 20 mmol·L-1 methane sulfonic acid solution was used as the eluent, CS12A(250 mm×4 mm) cation exchange column and a conductivity detector were employed to separate and detect the ions, with external standard method for quantification purpose. The LOD of UDMH was analyzed as 0.05 mg·L-1. Among the concentration range of 25—1 000 mg·L-1, the regression equation of the standard curve was Y=502 686X+239 795,R=0.999 7. The average recoveries under the addition level of 40 mg·L-1 and 400 mg·L-1 were 99.7 % and 99.5 % respectively. The RSD of 8 parallel samples was 1.10 %. Results show that it is a rapid, accurate and reliable method to determine unsymmetric dimethyl hydrazine by ion chromatography.
Key words: unsymmetric dimethyl hydrazine (UDMH); ion chromatography (IC); external sandard method
收稿日期: 20141117
作者简介: 孙素莉(1970—),女,实验师.